RECEPTACLES

BSPP Generator

RECEPTACLES

CAUTION

Receptacles may be marked with rating value greater than generator output capacity.

NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.

DO NOT overload the generator. See “Don’t Overload Generator”.

120/240 Volt AC, 30 Amp, Locking Receptacle

Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 8).You can use the same 4–wire cord if you plan to run a 120 Volt load.

Figure 8 — 120/240 Volt AC, 30 Amp Receptacle

4-Wire Cord Set

240V

120V 120/240 Volt AC, 30 Amp, Locking Receptacle 120V

W (Neutral)

120 Volt AC, 30 Amp Locking Receptacle

Use a NEMA L5-30 plug with this receptacle. Connect a

3-wire cord set rated for 125 Volts AC at 30 Amps to the plug (Figure 9).

Figure 9 — 120 Volt AC, 30 Amp, Locking Receptacle

3-Wire Cord Set

NEMA L5-30

Neutral

120V

Hot

Ground (Green)

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts (3.6 kW) of power at 30 Amps.The outlet is protected against overload by a 2 pole GFCI circuit breaker.

Y (Hot)

X (Hot)

NEMA L14-30

Ground (Green)

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 6,500 watts of power (6.5 kW) at 27.1 Amps for 120 Volts or 240 Volts.The outlet is protected against overload by a 2 pole GFCI circuit breaker.

12