Briggs & Stratton 01933-1 Troubleshooting, Problem, Cause, Correction, generator is running

Models: 01933-1

1 56
Download 56 pages 56.55 Kb
Page 18
Image 18
TROUBLESHOOTING

BSPP Generator

TROUBLESHOOTING

Problem

Cause

Correction

 

 

 

 

 

 

1.

One of the circuit breakers is open.

1.

Reset circuit breaker.

 

2.

Fault in generator.

2.

Contact Authorized service facility.

No AC output is available, but

3.

Poor connection or defective cord

3.

Check and repair.

generator is running.

 

set.

 

 

 

4.

Connected device is bad.

4.

Connect another device that is in

 

 

 

 

good condition.

 

 

 

 

 

Generator runs good at no-load

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

 

 

 

but "bogs" down" when loads are

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

connected.

3.

Shorted generator circuit.

3.

Contact Authorized service facility.

 

 

 

 

Generator will not start; or starts

Low oil level.

Fill crankcase to proper level or place

and runs rough.

 

 

generator on level surface.

 

 

 

 

 

Generator shuts down during

1.

Out of fuel.

1.

Fill fuel tank.

2.

Low oil level.

2.

Fill crankcase to proper level or

operation.

 

 

 

place generator on level surface.

 

 

 

 

 

 

 

Generator lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 

18

Page 18
Image 18