USER’S GUIDE

Table 1: Serial Interface Parameters Settings

Selector

Parameters

On (up)

 

Off (down)

1

Baud Rate

See Table 2.

 

 

 

 

 

 

2

Baud Rate

See Table 2.

 

 

 

 

8 bits

3

Data Length

7 bits

 

 

 

 

 

1 bit

4

Stop Bit

2 bits

 

 

 

 

 

 

 

5

Parity

See Table 3.

 

 

 

 

 

 

6

Parity

See Table 3.

 

 

 

 

DTR only

7

Protocol

Xon/Xoff + DTR

 

 

 

 

 

 

Off

8

Robust Xon

On

 

 

 

 

 

 

 

Table 2: Baud Rate Settings

 

 

 

 

 

 

 

 

 

Selector 1

Selector 2

For RS-422A

 

For RS-232C

 

 

 

 

 

 

Off

Off

 

57600

9600

 

 

 

 

 

 

On

Off

 

9600

4800

 

 

 

 

 

 

Off

On

 

1200

1200

 

 

 

 

 

 

On

On

 

19200

19200

 

 

 

 

 

Table 3: Parity Settings

 

 

 

 

 

 

 

 

 

Selector 1

Selector 2

Parity

 

 

 

 

 

 

 

On

On

Odd

 

 

 

 

 

 

 

On

Off

Even

 

 

 

 

 

 

 

Off

None

 

 

 

 

 

 

 

 