Brother HL-600 manual Bits

Models: HL-600

1 84
Download 84 pages 49.69 Kb
Page 38
Image 38

USER’S GUIDE

Table 1: Serial Interface Parameters Settings

Selector

Parameters

On (up)

 

Off (down)

1

Baud Rate

See Table 2.

 

 

 

 

 

 

2

Baud Rate

See Table 2.

 

 

 

 

8 bits

3

Data Length

7 bits

 

 

 

 

 

1 bit

4

Stop Bit

2 bits

 

 

 

 

 

 

 

5

Parity

See Table 3.

 

 

 

 

 

 

6

Parity

See Table 3.

 

 

 

 

DTR only

7

Protocol

Xon/Xoff + DTR

 

 

 

 

 

 

Off

8

Robust Xon

On

 

 

 

 

 

 

 

Table 2: Baud Rate Settings

 

 

 

 

 

 

 

 

 

Selector 1

Selector 2

For RS-422A

 

For RS-232C

 

 

 

 

 

 

Off

Off

 

57600

9600

 

 

 

 

 

 

On

Off

 

9600

4800

 

 

 

 

 

 

Off

On

 

1200

1200

 

 

 

 

 

 

On

On

 

19200

19200

 

 

 

 

 

Table 3: Parity Settings

 

 

 

 

 

 

 

 

 

Selector 1

Selector 2

Parity

 

 

 

 

 

 

 

On

On

Odd

 

 

 

 

 

 

 

On

Off

Even

 

 

 

 

 

 

 

Off

None

 

 

 

 

 

 

 

 

Caution

The factory settings are indicated in bold.

If the robust Xon setting is turned on with selector 8, the printer sends Xon signals at one second intervals to the connected computer until it receives data. It is effective only if selector 7 is set to the On position for the Xon/Xoff plus DTR setting.

4–4

Page 38
Image 38
Brother HL-600 manual Bits