Bryant 583B manual PERFORMANCE DATA cont STANDARD INDOOR PSC MOTOR, COOLING CAPACITIES cont

Models: 583B

1 28
Download 28 pages 39.19 Kb
Page 14
Image 14
PERFORMANCE DATA (cont)

PERFORMANCE DATA (cont)

STANDARD INDOOR PSC MOTOR

COOLING CAPACITIES (cont)

583B036 COOLING PERFORMANCE TABLE

 

Temp (F)

 

 

 

Evaporator Air — CFM/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Air

 

900/0.09

 

 

1200/0.13

 

 

1500/0.18

 

 

Entering

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

62

67

72

62

67

72

62

67

72

 

 

 

 

 

TC

35.2

38.7

41.6

36.6

39.8

41.9

37.3

39.5

41.5

75

 

SHC

30.3

25.5

20.7

34.0

28.0

21.6

37.3

29.3

21.6

 

 

kW

2.58

2.61

2.61

2.79

2.84

2.83

3.03

3.14

3.14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

32.9

36.9

39.9

34.8

37.9

40.2

35.5

37.7

39.8

85

 

SHC

28.7

24.8

20.1

33.3

27.4

21.0

35.5

28.8

21.1

 

 

kW

2.83

2.88

2.89

3.05

3.11

3.12

3.28

3.43

3.43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

31.0

34.9

37.9

32.4

35.9

38.3

33.8

35.7

37.8

95

 

SHC

27.9

24.0

19.3

30.8

26.7

20.3

33.8

28.0

20.5

 

 

kW

3.11

3.19

3.20

3.33

3.42

3.43

3.56

3.74

3.73

 

 

TC

27.9

31.5

34.3

29.3

32.2

34.6

30.7

32.0

34.0

105

 

SHC

26.0

22.2

17.7

28.3

24.8

18.6

30.7

26.5

18.7

 

 

kW

3.49

3.59

3.60

3.73

3.82

3.82

3.97

4.15

4.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

25.5

28.8

31.4

27.5

29.4

31.5

28.3

29.2

31.0

115

 

SHC

24.7

21.0

16.5

27.5

23.4

17.5

28.3

25.2

17.6

 

 

kW

3.85

3.96

3.96

4.07

4.19

4.19

4.34

4.46

4.51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

22.2

24.6

27.0

24.0

25.0

27.0

24.5

24.8

26.3

125

 

SHC

22.2

19.1

14.8

24.0

21.5

15.8

24.5

23.0

15.8

 

 

kW

4.48

4.59

4.61

4.71

4.79

4.84

4.98

5.09

5.15

 

 

 

 

 

 

 

 

 

 

 

583B042 COOLING PERFORMANCE TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

Evaporator Air — CFM/BF

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Air

 

1050 / 0.10

 

 

1500 / 0.13

 

 

1750 / 0.17

 

 

Entering

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

62

67

72

62

67

72

62

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

40.9

44.6

48.1

42.3

45.8

49.1

43.1

45.9

48.8

75

 

SHC

35.2

29.5

23.4

39.8

32.4

24.6

43.1

34.4

25.1

 

 

kW

2.93

2.97

2.99

3.20

3.27

3.30

3.48

3.70

3.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

38.8

42.7

46.3

40.4

43.8

47.1

41.5

43.9

46.9

85

 

SHC

34.2

28.7

22.8

39.0

31.7

24.0

41.5

33.8

24.5

 

 

kW

3.26

3.31

3.35

3.53

3.62

3.66

3.76

4.04

4.07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

36.5

40.7

44.2

38.1

41.7

45.0

39.8

41.6

44.7

95

 

SHC

33.1

27.8

22.0

38.1

30.9

23.3

39.8

33.0

23.9

 

 

kW

3.60

3.70

3.73

3.87

4.01

4.03

4.15

4.43

4.45

 

 

TC

31.9

35.8

39.4

33.9

36.8

40.0

35.5

36.5

39.8

105

 

SHC

30.3

25.3

20.0

33.9

28.5

21.3

35.5

30.7

22.1

 

 

kW

4.26

4.42

4.46

4.50

4.75

4.78

4.91

5.17

5.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

28.6

32.0

35.6

30.8

32.9

36.0

32.2

32.7

35.5

115

 

SHC

28.6

23.6

18.6

30.8

26.9

20.0

32.2

29.1

20.6

 

 

kW

4.92

5.10

5.18

5.06

5.47

5.49

5.63

5.84

5.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

25.3

28.4

32.0

27.8

29.1

32.1

29.0

28.9

31.3

125

 

SHC

26.6

21.8

17.1

27.8

25.1

18.5

29.0

27.2

19.0

 

 

kW

5.62

5.84

5.97

5.66

6.24

6.26

6.41

6.57

6.73

 

 

 

 

 

 

 

 

 

 

 

 

See Legend and Notes on page 15.