GUIDE SPECIFICATIONS continued

K.Electrical Requirements:

All unit power wiring shall enter the unit cabinet at a single location.

L.Motors:

1.Compressor motors shall be of the refrigerant-cooled type with line-break thermal and current overload pro- tection.

2.All fan motors shall have permanently lubricated bear- ings, and inherent, automatic reset, thermal overload protection.

3.Condenser fan motor shall be totally enclosed.

M.Grille:

1.Louvered Grille:

Louvered grille shall be factory-installed to provide hail guard and vandalism protection.

N.Duct Conversion:

Shall be available with the use of included duct covers. O. Special Features:

1.ICM Indoor Blower FIOP:

Integral control motor shall be a factory installed option for optimizing comfort levels in all operating modes and increasing system efficiency.

2.Coil Options:

Shall include factory-installed optional copper/ copper and vinyl-coated refrigerant coils.

3.Economizer:

a.Economizer controls capable of providing free cool- ing using outside air.

b.Equipped with low leakage dampers not to exceed 3% leakage, at 1.0 in. wg pressure differential.

c.Spring return motor shuts off outdoor damper on power failure.

4.Flat Roof Curb:

Curbs shall have seal strip and a wood nailer for flash- ing and shall be installed per manufacturer’s instruc- tions.

5.Manual Outdoor Air Damper:

Package shall consist of damper, birdscreen, and rain- hood which can be preset to admit outdoor air for year- round ventilation.

6.Thermostat:

To provide for one-stage heating and cooling in addition manual or automatic changeover and indoor fan control.

7.Natural-to-Propane Conversion Kit:

Shall be complete with all required hardware to convert to liquid propane (LP) operation.

8.Low Ambient Package:

Shall consist of a solid-state control and condenser coil temperature sensor for controlling condenser-fan mo- tor operation, which shall allow unit to operate down to 0° F outdoor ambient temperature.

9.Filter Rack Kit:

Shall provide filter mounting for downflow applications.

10.Square-To-Round Duct Transitions:

Shall have the ability to convert the supply and return openings from rectangular to round.

11.Compressor Protection (Time Guard® II Kit) Solid-state control shall protect compressor by prevent- ing “short cycling.”

12.Crankcase Heater:

Shall provide anti-floodback protection for low-load cooling applications.

13.High Altitude Kit:

Shall consist of natural gas orifices to compensate for gas heat operation at 2001 to 6000 ft above sea level.

14.Low NOx (Natural Gas only) option:

Shall provide NOx reduction to values below 40 nano- grams/joule to meet California emission requirements.

15.Compressor Hard Start Kit:

Shall provide additional starting torque for single-phase compressors. (Single phase only).

16.Rigging kit includes lifting brackets which are inserted into the basepan handholds to rig unit for rooftop appli- cations.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

UNIT MUST BE INSTALLED IN ACCORDANCE

WITH INSTALLATION INSTRUCTIONS

Cancels: PDS 583B.24.2

Form PDS 583B.24.3

© 2001 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231

PRINTED IN U.S.A.

Catalog No. 5258-305 5-01

— 28—

Page 28
Image 28
Bryant 583B manual Guide Specifications

583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.