SERVICE (cont.)

SERVICE (cont.)

TANK HEATER (Cont.)

13.Secure sprayhead tube to hood using a hex nut.

14.Install sprayhead.

15.Reconnect the wires to the limit thermostat, tank heater and control thermostat. See limit thermo- stat and control thermostat sections in this manual when reconnecting wires.

16.Install fill basin, secure with tank inlet fitting and gasket. Insert water supply line through grommet in fill basin.

17.Refer to Fig.13 when reconnecting the tank heater wires.

WHI to Terminal Block (White Insert on 230V Two Wire Models)

RED to Terminal Block (Red Insert on 120/240V Three Wire Models or 200V and 240V Two Wire Models

BLK to Control Ther- mostat (Brewers W/Out Faucet)

Thermal Cut-Off to BLK from Control Thermo- stat (Brewers W/Fau- cet)

P1168.71

FIG. 13 TANK HEATER TERMINALS