TROUBLESHOOTING (cont.)
PROBLEM
Spitting or excessive steaming (cont.)
Dripping from sprayhead
PROBABLE CAUSE
2.Control Thermostat
1.Syphon System
2. Lime
CAUTION - Tank and tank com- ponents should be delimed regularly depending on local water conditions. Excessive mineral
3. Solenoid Valve
REMEDY
Refer to Service - Control Thermostat for testing proce- dures. See page 14
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for excessive lime deposits. Delime as required.
Remove the solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary. See page 18
Water flows into tank continu- ously (ON/OFF Switch "ON")
Water flows into tank continu- ously (ON/OFF Switch "OFF")
Beverage overflows dispenser
1. Timer
1. Solenoid Valve
1.Dispenser
2.Timer
3.Solenoid Valve
Page 11
Refer to Service - Timer for testing procedures. See page 25 or 27
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 18
The dispenser must be com- pletely empty before starting a brew cycle.
Refer to Service - Timer for testing procedures. See page 25 or 27
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 18
10478 061500