Bunn CRT5, CRTF5 service manual SERVICE cont DIGITAL BREW TIMER Late Models

Models: CRT5 CRTF5

1 32
Download 32 pages 58.84 Kb
Page 27
Image 27
SERVICE (cont.)

SERVICE (cont.)

DIGITAL BREW TIMER (Late Models)

P2186.45

FIG. 20 DIGITAL BREW TIMER

Location:

The timer is located inside the front of the trunk on the upper right side of component bracket.

Test Procedure

NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.

1.Disconnect the brewer from the power source and remove the front access panel.

2.Remove the two #8-32 screws securing circuit board to the mounting bracket.

3.Remove circuit board and spacers (as required).

4.With a voltmeter, check the voltage across termi- nals TL1 and TL2 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.

b)200 to 240 volts ac on two wire 200 volt or 240 volt models.

5.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.

6.Disconnect the white/blue wire from terminal TL3 and the blue/black wire from terminal TL5. With a voltmeter, check for continuity across the two wires when the "ON/OFF" switch is in the "ON" position (upper) and the START switch is pressed. Connect the brewer to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.

b)200 to 240 volts ac for two wire 200 volt or 240 volt models.

If continuity is present as described, reconnect the wires and proceed to #7.

If continuity is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.

7.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 0 volts.

If voltage is as described, proceed to #8.

If voltage is not as described, disconnect the brewer from the power source and replace the timer.

8.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indica- tion must be as follows:

a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.

b)200 to 240 volts ac on two wire 200 volt or 240 volt models.

If voltage is present as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume.

If voltage is not present as described, disconnect the brewer from the power source and replace the timer.

Removal and Replacement:

1.Remove the two #8-32 screws securing circuit board to the mounting bracket.

2.Remove circuit board and spacers (as required).

3.Remove all wires from the timer.