15.CONNECTING HYDRAULICS (Refer to Fig. 5 and Fig. 6):

13.Install joint to the cable end and snug up the jamb nut. Connect the cable to the control valve spools (Refer to Fig. 3 for correct location of cables to spools).

14.Place joint in slot on end of spool and place pin in hole. Place “O” ring in inset of valve around spool and run cap up on threads of cable end. Pull flange up around the cap and attach to the valve using the (2) m5 x 20 socket head screws provided. Pull washer up to base of cap and run the nut to contact the washer.

15.CONNECTING HYDRAULICS (Refer to Fig. 5 and Fig. 6):

Attach (4) 68” hose assemblies by plugging into the matching color on the female halves mounted on the valve (Refer to Fig. 5).

16.Attach the (4) hoses from the valve to the metal lines on the boom frame on the right hand side of loader. Use the (4) 3/4” JIC x 3/4” JIC male unions provided.

Attach as follows: (Refer to Fig. 5).

Port A1 (Blue) to head end of lift cylinder.

Port B1 (Red) to rod end of lift cylinder.

Port A2 (Yellow) to rod end of bucket cylinder.

Port B2 (Green) to head end of bucket cylinder.

Fig. 5

RED

BLUE

YELLOW

 

 

GREEN

TO METAL LINES ON LOADER FRAME.

TO SUPPLY PORTS AT REAR OF TRACTOR.

PRESSUREAttach as follows: (Refer to Fig. 5).Manual backgroundManual backgroundManual background

(RED) - PORT B1 TO ROD END LIFT CYLINDER. (BLUE) - PORT A1 TO HEAD END LIFT CYLINDER. (YELLOW) - PORT A2 TO ROD END BUCKET CYLINDER. (GREEN) - PORT B2 TO HEAD END BUCKET CYLINDER.