Cabletron Systems NB30 manual Bridge State on Interface, OK/SQE on

Models: NB30

1 64
Download 64 pages 18.72 Kb
Page 31
Image 31

NB-30 Bridging

Bridge State on Interface

This color-coded text box indicates the state of bridging over the port interface. Note that this state (and its corresponding color code) will also be reßected on the NB-20E/25E Port display in the Chassis View window. Possible bridge states and their corresponding colors are:

FWD (Forwarding)

(Green) The port is on-line and forwarding packets

 

across the NB-20E/25E from one network segment to

 

another.

DIS (Disabled)

(Blue) Bridging at the port has been disabled by

 

management; no trafÞc can be received or forwarded on

 

this port, including conÞguration information for the

 

bridged topology.

LRN (Learning)

(Magenta) The Forwarding database is being created, or

 

the Spanning Tree Algorithm is being executed because

 

of a network topology change. The port is monitoring

 

network trafÞc, and learning network addresses.

LIS (Listening)

(Magenta) The port is not adding information to the

 

Þltering database. It is monitoring Bridge Protocol Data

 

Unit (BPDU) trafÞc while preparing to move to the

 

forwarding state.

BLK (Blocking)

(Orange) The port is on-line, but Þltering trafÞc from

 

going across the NB-20E/25E from one network segment

 

to another. Bridge topology information will be

 

forwarded by the port.

BRK (Broken)

(Red) The physical interface has malfunctioned.

The port Status is taken from CabletronÕs proprietary Bridge MIB, as the NB-30 is an older bridge. Potential status conditions are:

OFF

The port is off, due to a failed network interface chip

 

associated with that port.

OK/SQE ON

The port is communicating with the network and the

 

transceiver making the connection to the network has

 

SQE enabled.

OK/SQE OFF

The port is communicating with the network and the

 

transceiver making the connection to the network has

 

SQE disabled.

CARRIER LOST

Communication with the network has not been

 

established or has been lost

Bridge Status

3-5

Page 31
Image 31