3.2.4.2 Installing LDRAM and SDRAM SIMMs

Preparing the NBR for Installation

3.2.4.2 Installing LDRAM and SDRAM SIMMs

To install an LDRAM or SDRAM SIMM, see Figure 3-4 and the steps below.

SIMM Hole

SIMM Slot

SIMM

Connector

Teeth

SIMM Slot

Post

Connector Clip

1092_09

Figure 3-4 Installing an LDRAM or SDRAM SIMM

Install an LDRAM or SDRAM SIMM as follows:

!

CAUTION

The components and boards associated with the NBR are sensitive to static discharges. Be sure to use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to the NBR.

1.Insert the SIMM between the connector teeth in the SIMM slot.

2.Pivot the SIMM back until it locks into the clips in the SIMM slot, and the SIMM holes fit over the SIMM slot posts.

3.2.5 Adding/Replacing EPIMs

This section contains procedures on how to add/replace an Ethernet Port Interface Module (EPIM) to upgrade or change the capabilities of your hub. See Figure 3-5. After installing your new EPIM, refer to appropriate EPIM sections in this chapter for connecting media types and to verify proper operation.