The transmitter power levels given above are Peak Power Levels after optical overshoot. Use a Peak Power Meter to compare the values given above to those measured on any particular port. To measure power levels with an Average Power Meter, add 3 dBm to the average power measurement to compare the average power values measured to the values listed above (i.e., -33.5 dBm average + 3 dBm = -30.5 dBm peak).

Appendix B: EPIM Specifications

Parameter

Typical

Minimum

Maximum

 

 

 

 

 

 

 

 

Transmitter Peak

1300 nm

1270 nm

1330 nm

Wave Length

 

 

 

 

 

 

 

Spectral Width

60 nm

-

100 nm

 

 

 

 

Rise Time

3.0 ns

2.7 ns

5.0 ns

 

 

 

 

Fall Time

2.5 ns

2.2 ns

5.0 ns

 

 

 

 

Duty Cycle

50.1%

49.6%

50.7%

 

 

 

 

Bit Error Rate

Better than 10-10

 

 

 

 

 

The transmitter power levels given above are Peak Power Levels after optical overshoot. Use a Peak Power Meter to compare the values given above to those measured on any particular port. To measure power levels with an Average Power Meter, add 3 dBm to the average power measurement to compare the average power values measured to the values listed above (i.e., -33.5 dBm average + 3 dBm = -30.5 dBm peak).