Cabletron Systems NBR-220 Troubleshooting Checklist, NBR-SERIES Installation Guide, Page, Problem

Models: NBR-620 NBR-220 NBR-420

1 73
Download 73 pages 57.23 Kb
Page 46
Image 46

 

Troubleshooting Checklist

Table 4-2 Troubleshooting Checklist (Continued)

 

 

 

Problem

Possible Causes

Recommended

Action

 

 

 

 

 

 

 

 

User parameters (IP

NVRAM reset switch

See Chapter 3 for

address, Device and

has been toggled and

proper use of the

Module name, etc.) are

user-entered

NVRAM switch.

lost when device is

parameters have been

 

powered down.

reset to factory default.

 

 

NVRAM may be

If NVRAM is defective,

 

defective.

call Cabletron Systems

 

 

Technical Support.

 

 

 

No power to an external

AUI cable may be

Replace AUI cable.

transceiver connected

defective.

 

to an EPIM-A.

 

 

 

Transceiver may be

Replace transceiver.

 

defective.

 

 

EPIM is defective.

Replace EPIM.

 

 

 

High number of

External transceiver

Disable SQE.

collisions on EPIM port.

has SQE enabled.

 

 

 

 

Port(s) go into standby

Configurations where

Discuss these

for no apparent reason.

devices connect across

configurations with

 

NBR channels can

Cabletron Systems

 

cause the NBR to

Technical Support

 

detect a looped

before implementing

 

condition.

them into your network.

 

 

 