Using the TSX-1620 Hub View

2-14 Monitoring Device Performance

Tp Frames Filtered
Displays the percentage of valid frames received by this port that were discarded
by the forwarding process.
Sr Frames Forwarded
Displays the percentage of Source Route bridging frames that have been
transmitted to or received from the port’s attached segment that have been
forwarded to their destination.
Bridge Port Number
Displays the port’s bridge port number.
Port Color Codes for the Bridge Application Display
No matter which Bridge Port Status display form is selected, each bridge interface
is color-coded to reflect the Bridge Port state, as follows:
Blue — The bridge port is administratively Disabled.
Magenta — The bridge port is in the Listening or Learning state.
Green — The bridge port is on line and Forwarding.
Orange — The bridge port is currently Blocking.
Red — The bridge port is malfunctioning.
Gray — No information is being returned from the interface; its ifOperStatus
is not being returned.
Clearing Statistical Information
The Clear Stats selection in the TSX-1620 Module menu will reset the device’s
statistical counters to zero. To reset the TSX-1620’s statistical counters:
1. Click on the module index or module type to display the Module menu (see
Figure 2-3 on page 2-5).
2. Drag down to Clear Stats, and release. The TSX-1620’s statistical counters
will reset to 0, and begin updating at the rate determined by the Statistics
polling interval.