Standard, Economy and Sleep Heating Modes

Your new spa is equipped with a heating feature that gives you complete control of the heating system. When the spa is powered up, it will automatically start in standard heating mode.

St will light briefly on the main display. In this mode, the heating system will automatically maintain the set spa temperature. In the economy- heating mode, the heating system will only activate during filtration times.

Ec will display solid if temperature is not current and will alternate with spa temperature if measured temperature is current.

Economy mode will heat the water to the set temperature while Sleep mode, indicated by a SL on the main display, will also only activate the heater during the filtering cycles but will only heat the water to within 20°F (10°C) of the set temperature. Like Economy mode, SL will display solid when temperature is not current and will alternate with actual temperature when it is current.

NOTE: Displayed temperature will only be current after the pump has been running for at least two minutes.

Switching Modes

Press Temp button followed by the Light button.

Press the same sequence to switch to the next mode.

Jets

Press the Jets button:

Once to activate low speed pump.

Twice to activate high speed.

Three times to turn pump off.

Light

Press the Light button to turn on the light. Press it once again to turn the light off. All optional lighting such as the control panel light and cabinet perimeter lighting is controlled by the Light button and will turn on and off with the spa light.

Option

Press the Option button to turn on the pump 2. Press it once again to turn off the pump 2 (6200 control only).

2010 Portable Spa

6300 Control - Pump 2 and Pump 3 Sequence

Press Option button once to activate high speed pump 2.

Press Option button twice to activate high speed pump 3 and high speed pump 2.

Press three times to activate pump 3 high speed only.

Press four times to turn pumps off.

“Green Pack” Operation

Spas with the “Green Pack” option require approximately 20% less power to operate. Once the spa is properly installed, it does not require any special operation. This is for your information only.

When JETS 1 is pressed, the heater will operate at 220V. When JETS 2 or OPTION is pressed (depending on which control panel you have), the heater will automatically switch to operate at 110V.

With the “Green Pack”, your spa will never use more than 30 amps while in operation.

Automatic Time outs

These features will automatically turn themselves off during periods of continuous use:

Low speed pump

After 4 hours

High speed pumps

After 15 minutes

Optional circulation pump

After 15 minutes

Optional turbo

After 15 minutes

Spa light

After 4 hours

Setting Filtration Cycles

Your spa is programmed to filter twice a day. The first cycle will begin 6 minutes after the spa is turned on and the second cycle 12 hours later. The factory has programmed the cycle to last for 2 hours but this can be switched to 4, 6, or 8 hours depending on your requirements. To set filtration time, turn off the power to the spa at the time of day you would like one of the filtration cycles to begin then turn back on after 30 seconds. When power has been restored, press the Temp button then the Jets button. Press Temp button again to change the filtering cycle duration. When desired duration is selected press the Jets button to exit.

At the beginning of each filtering cycle the Turbo system will run for approximately 30 seconds. The low speed pump will run for the duration of the filtering cycle and if an Ozone system is installed it will be activated. During filtering, FC will appear on the main display.