Clean up Cycle

16

Operating SpaYour

The “FILTER 1” indicator icon will light when filter 1 is running.

The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM.

The “FILTER 2” indicator icon will light when filter

2 is running.

The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to run according to your desired programming.

Clean up Cycle

When the pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for one hour.

Ozone

This is an optional feature. On most systems, the ozone

generator (if installed) runs during filter cycles (except

when pump 1 is operating at high speed on a non-circ ulating system) and during clean-up cycles. On some systems, the ozone generator operates whenever

the pump runs. If your system is configured with the

optional ozone disable feature, the ozone generator will turn off for one hour any time a function button

(“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed.

Freeze Protection

If the temperature sensors detect a drop to 44°F

within the heater, the pump automatically activates to provide freeze protection. The equipment stays on until four minutes after the sensors detect that

the spa temperature has risen to 45°F or higher. In

colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a four-minute delay in turnoff.

2010 Portable Spa