Cal Spas LTR20101000 Troubleshooting, Symptom, Possible Causes, Possible Solutions, Heat Problems

Models: LTR20101000

1 60
Download 60 pages 6.26 Kb
Page 54
Image 54
Troubleshooting

52 Appendix

Troubleshooting

Symptom

Possible Causes

 

Possible Solutions

System / Power Problems

 

 

 

System does not work

Power is turned off

 

Reset spa

 

Control pad and spa

No electrical power to spa

 

Turn on or reset the GFCI circuit breaker.

equipment do not

 

 

If this does not solve the problem, have

operate

 

 

a qualified electrician check the electrical

 

 

 

service.

 

 

 

 

 

The 20 or 30A fuse, depending on

 

Contact your dealer

 

the system, has blown

 

 

The spa does not turn

Spa is trying to heat up

 

Check the temperature setting is in

off

 

 

Standard mode

 

 

 

 

 

Spa is in filter cycle

 

Normal. No adjustment necessary

 

 

 

 

 

Spa is in Standard mode

 

Check setting

Control panel displays

An error may have has occurred

 

See Diagnostic Messages on page 18 for

a message

 

 

message code meanings

GFCI breaker trips

Improper wiring to spa or GFCI

 

Consult with a qualified electrician

repeatedly

breaker is defective

 

 

 

 

 

 

 

There is a defective component on

 

Contact your dealer

 

the spa

 

 

Heat Problems

 

 

 

Spa does not heat

Heating mode not selected

 

See control panel instructions on pages

 

 

 

12 through 16

 

 

 

 

 

Water level is too low

 

Add water to correct level

 

 

 

 

 

No electrical power to spa

 

Turn on or reset the GFCI circuit breaker.

 

 

 

If this does not solve the problem, have

 

 

 

a qualified electrician check the electrical

 

 

 

service.

 

 

 

 

 

Heater is defective

 

Contact your dealer

 

 

 

 

 

Gate valve is partially or fully closed

 

Open gate valves. Note: Never operate

 

 

 

your spa with the gate valves closed!

Spa gets warm but

Thermostat has been turned down

 

Set control panel to a higher temperature

does not get hot

 

 

 

Insufficient filtration time

 

Increase filtration time

 

 

 

 

 

 

 

Water level is too low

 

Add water to correct level

 

 

 

 

 

No electrical power to spa

 

Turn on or reset the GFCI circuit breaker.

 

 

 

If this does not solve the problem, have

 

 

 

a qualified electrician check the electrical

 

 

 

service.

 

 

 

 

 

Dirty filter cartridge

 

Clean filter cartridge

 

 

 

 

 

Gate valves closed

 

Open gate valves

 

 

 

 

 

Spa cover improperly positioned

 

Align spa cover

Spa gets too hot

Filtration time is set too long

 

Reduce filtration cycles, especially during

 

 

 

summer months

 

 

 

 

2010 Portable Spa

www.calspas.com

LTR20101000, Rev. C

Page 54
Image 54
Cal Spas LTR20101000 Troubleshooting, Symptom, Possible Causes, Possible Solutions, System / Power Problems, Heat Problems