18
Operating SpaYour
LF | Persistent low flow problems. (Displays | Follow action required for “HFL” message. Heating |
| on the fifth occurrence of the “HFL” | capacity of the spa will not reset automatically; you |
| message within 24 hours.) Heater is shut | may press any button to reset. |
| down, but other spa functions continue |
|
| to run normally. |
|
|
|
|
dr | Inadequate water detected in heater. | Check water level in spa. Refill if necessary. If the |
|
| water level is okay, make sure the pumps have been |
|
| primed. Press any button to reset. |
|
|
|
dry | Inadequate water detected in heater. | Follow action required for “dr” message. Spa will not |
| (Displays on third occurrence of “dr” | automatically reset; you may press any button to |
| message.) Spa is shut down. | reset. |
|
|
|
Pr | When your spa is first actuated, it will | The Priming mode will last for up to four minutes |
| go into Priming mode. | and then the spa will begin to heat and maintain the |
|
| water temperature in the Standard mode. |
Temperature unknown | After the pump has been running for two minutes, | |
|
| the temperature will be displayed. |
- - - - - - | Temperature not current in Economy or | In Economy or Sleep mode, the pump may be off for |
| Sleep mode. | hours outside a filter. If you wish to see the current |
|
| spa temperature, either switch to Standard mode or |
|
| turn Jets1 on for at least two minutes. |
|
|
|
BUF | Internal problem detected. | Repair required. Contact your dealer or service |
|
| organization. |
|
|
|
Stby | Standby Mode has been activated by | Press any button to leave Standby Mode and return |
| pressing a button combination on the | to normal operation. |
| user panel. |
|
|
|
|
SF | Safety Suction. | Spa is shut down. The display will show “SF” when a |
|
| vacuum switch closes. All functions will turn off and |
|
| the system will be disabled until a panel button is |
|
| pressed. |
|
|
|