Cal Spas LTR20101001 Operating Your Spa, and 6205 Electronic Control Operation, OperatingYour

Models: LTR20101001

1 48
Download 48 pages 32.1 Kb
Page 12
Image 12
Operating Your Spa

12

Spa

Operating Your Spa

6105 and 6205 Electronic Control Operation

OperatingYour

Initial Start up

When first powered up, it will automatically revert to Priming mode. A Pr on the topside display will indicate this. Priming mode will be active for less than five minutes at which time the heater will be activated and the water temperature will be maintained in Standard mode. The spa will heat to 37.5°C at start up until the set temperature is changed as described below.

Temperature Adjustment

(Range 26°C to 40°C)

The electronic control panels display the actual water temperature in degrees Celsius. The displayed temperature will only be current after the pump has been running for at least 2 minutes.

To display the temperature that the spa is set to:

Press the Temp button. The temperature setting will flash.

While the display is flashing, each time you press Temp button, the set temperature will change up or down one degree.

If the desired temperature is opposite of the direction each press of the button is making, release button, allow display to stop flashing and then press Temp button to change temperature the other direction.

Standard, Economy and Sleep Heating Modes

Your new spa is equipped with a heating feature that gives you complete control of the heating system. When the spa is powered up, it will automatically start in standard heating mode.

St will light briefly on the main display. In this mode, the heating system will automatically maintain the set spa temperature. In the economy-heating mode, the heating system will only activate during filtration times.

Ec will display solid if temperature is not current and will alternate with spa temperature if measured temperature is current.

Economy mode will heat the water to the set temperature while Sleep mode, indicated by a SL on the main display, will also only activate the heater during the filtering cycles but will only heat the water to within 10°C of the set temperature.

Like Economy mode, SL will display solid when temperature is not current and will alternate with actual temperature when it is current.

NOTE: Displayed temperature will only be current after the pump has been running for at least two minutes.

Switching Modes

Press Temp button followed by the Light button.

Press the same sequence to switch to the next mode.

Jets

Press the Jets button:

Once to activate low speed pump.

Twice to activate high speed.

Three times to return to turn pump off.