SDM-SIO4 User Guide
*Table 1 Program
01: 1.0 Execution Interval (seconds)
;test flag 1 – if not set tell the
1:If Flag/Port (P91)
1:21 Do if Flag 1 is Low
2: 30 | Then Do |
;tell the SDM-SIO4 to use filter string 100
2:
1: 1 | Reps | |
2: 0 | Address | |
3: | 1 | Send/Receive Port 1 |
4: | 2054 | Command |
5:9100 1st Parameters
6:0 2nd Parameters
7:0 Values per Rep
8:0000 Loc [ _________ ]
9: | 0 | Mult |
10: | 0 | Offset |
;a minimum delay of 4ms is required by the above P113
3:Excitation with Delay (P22)
1:1 Ex Channel
2:0 Delay W/Ex (units = 0.01 sec)
3:1 Delay After Ex (units = 0.01 sec)
4:0 mV Excitation
;set flag 1 to instruct the
4:Do (P86)
1:11 Set Flag 1 High
;end of filter setup
5:End (P95)
;poll
6:
1: 1 | Reps |
2: 0 | Address |
3: 1 | Send/Receive Port 1 |
4: 1 | Command |
5: 0 | 1st Parameters |
6: 0 | 2nd Parameters |
7: 1 | Values per Rep |
8: 1 | Loc [ _________ ] |
9: 1 | Mult |
10: 0 | Offset |