Section 5. Programming the Datalogger

;set serial mode to DTR, RTS always set, ignore CTS, 1 stop bit no parity, ;8 bit data length, 9600 baud and no handshake delay.

2:SDM-SIO4 (P113)

1: 1

Reps

2: 0

Address

3: 1

Send/Receive Port 1

4: 2049

Command

5: 3146

1st Parameters

6: 0

2nd Parameters

7: 0

Values per Rep

8:0000 Loc [ _________ ]

9:1.0 Mult

10:0.0 Offset

;set up a simple filter 1999 search for floating point number.

3:SDM-SIO4 (P113)

1: 1

Reps

2: 0

Address

3: 1

Send/Receive Port 1

4: 2054

Command

5: 1999

1st Parameters

6: 0

2nd Parameters

7: 0

Values per Rep

8:0000 Loc [ _________ ]

9:1.0 Mult

10:0.0 Offset

;the set up filter command requires a delay of 4ms, the nearest we can get ;is 10ms with P22.

4:Excitation with Delay (P22)

1:1 Ex Channel

2:0 Delay W/Ex (units = 0.01 sec)

3:1 Delay After Ex (units = 0.01 sec)

4:0 mV Excitation

;set flag one high so the above will only be done once.

5:Do (P86)

1:11 Set Flag 1 High

;end of serial and filter setup.

6:End (P95)

;get two floating point numbers into locations 1 and 2.

7:SDM-SIO4 (P113)

1:

1

Reps

 

2:

0

Address

 

3:

1

Send/Receive Port 1

4:

4

Command

 

5:

0

1st Parameters

 

6:

0

2nd Parameters

 

7:

2

Values per Rep

 

8:

1

Loc [ Number

]

9:

1.0

Mult

 

10: 0.0

Offset

 

5-15

Page 45
Image 45
Campbell Hausfeld SDM-SIO4 manual Set flag one high so the above will only be done once, End of serial and filter setup