Section 5. Programming the Datalogger
;set serial mode to DTR, RTS always set, ignore CTS, 1 stop bit no parity, ;8 bit data length, 9600 baud and no handshake delay.
2:
1: 1 | Reps |
2: 0 | Address |
3: 1 | Send/Receive Port 1 |
4: 2049 | Command |
5: 3146 | 1st Parameters |
6: 0 | 2nd Parameters |
7: 0 | Values per Rep |
8:0000 Loc [ _________ ]
9:1.0 Mult
10:0.0 Offset
;set up a simple filter 1999 search for floating point number.
3:
1: 1 | Reps |
2: 0 | Address |
3: 1 | Send/Receive Port 1 |
4: 2054 | Command |
5: 1999 | 1st Parameters |
6: 0 | 2nd Parameters |
7: 0 | Values per Rep |
8:0000 Loc [ _________ ]
9:1.0 Mult
10:0.0 Offset
;the set up filter command requires a delay of 4ms, the nearest we can get ;is 10ms with P22.
4:Excitation with Delay (P22)
1:1 Ex Channel
2:0 Delay W/Ex (units = 0.01 sec)
3:1 Delay After Ex (units = 0.01 sec)
4:0 mV Excitation
;set flag one high so the above will only be done once.
5:Do (P86)
1:11 Set Flag 1 High
;end of serial and filter setup.
6:End (P95)
;get two floating point numbers into locations 1 and 2.
7:
1: | 1 | Reps |
|
2: | 0 | Address |
|
3: | 1 | Send/Receive Port 1 | |
4: | 4 | Command |
|
5: | 0 | 1st Parameters |
|
6: | 0 | 2nd Parameters |
|
7: | 2 | Values per Rep |
|
8: | 1 | Loc [ Number | ] |
9: | 1.0 | Mult |
|
10: 0.0 | Offset |
|