29
Special Features
Function Keys
The function keys (F1 to F6) on the operation panel can be
used to store frequently used functions, allowing the preset
function to be recalled at a single touch. The function keys
(F1 to F6) can store up to 6 function settings. (If the op-
tional operation keyboard is used, an additional 4 settings
can be stored.) The nineteen types of settings that can be
stored are described below.

Programming Function Keys

Use the procedure below to store a function in a function
key.
1Hold down the Clear key and the function key you want
to program for 2 seconds.
The number of the function to be stored appears on the
display.
Display Function Use the function keys
All setting Assignment
New File F1
Lighten Screen F4
Darken Screen F5
Standby mode F6
Rotate Right F3
Rotate Left F2
Skew Correction
Addon
margin Scanning P1
Adjust Margin
Adjust Sharpness P3
Picture Mode P4
Overlay Scanning
600DPI
Background erase P2
Auto centering
Scanner F1
Printer F4
See the following pages for descriptions of the func-
tions.
At shipment, P1 and P4 are assigned to the optional
operation keyboard.
2Use the selector keys (the plus and minus keys) to select
the function assigned to the function key.
3Press the function key to store the function.
Note
Function keys can also be programmed from the
application software. Refer to the manuals supplied
with the application for details.
F1 F
2
F
3
F
5
F
4
F
6
+
P1 P
2
P
3
P
4
or
(Optional keyboard)