Canon AXIS 1610 user manual Using the Test Button, Factory Default, Settings

Models: AXIS 1610

1 57
Download 57 pages 52.2 Kb
Page 49
Image 49

AXIS 1610 User’s Manual

Section 4: Management & Configuration

49

 

 

 

Using the Test Button

The test button is located on the front right hand side of the AXIS 1610 and is used for resetting the AXIS 1610 parameters to the factory default settings.

Factory Default

Follow the instructions below to reset the AXIS 1610 to the

Settings

factory default settings:

 

1.

Remove the external power supply to switch off the AXIS 1610.

 

 

2.

Press and hold down the test button, while you plug the external

 

 

power supply back in. Continue to hold down the test button,

 

 

until the network indicator begins to flash at one second

 

 

intervals. This should take at least 5 seconds.

 

3.

Release the test button and wait until the network indicator

 

 

flashes at least five times.

 

4.

Press and hold the test button again until the network indicator

 

 

remains constantly lit.

 

5.

Restart the AXIS 1610 by disconnecting and reconnecting the

 

 

external power supply.

 

The AXIS 1610 is now reset to factory default settings.

Note:

All parameters except the IP Address (IP_ADDR.) and the DHCP

 

 

Enable/Disable (DHCP_ENB) parameters are reset. If you want to

change these parameters, please use any of the tools presented in Configuration Overview, on page 32.

Page 49
Image 49
Canon AXIS 1610 user manual Using the Test Button, Factory Default, Settings