CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
42
5.2. Analog Monitor Output Selecting
The analog monitor output can be switched to monitor various operation and signal statuses.
This switching can be executed from [GALILEO] or [RS-232C command send].
Output contents
Terminal Power-on
Selection
Signal Description Signal Level (At Power-on)
A2 (Axis 1)
A6 (Axis 2)
Phase A of Encoder Head 1
Phase A of Encoder Head 2
Phase A of encoder after synthesis
* Positional deviation signal 1.46 mV / pulse
A3 (Axis 1)
A7 (Axis 2)
Position 0.091 mV / pulse
* Velocity 0.091 mV / pulse / 10 usec
Coarse angle
Fine angle
A4 (Axis 1)
A8 (Axis 2)
Phase B of Encoder Head 1
Phase B of Encoder Head 2
Phase B of encoder after synthesis
* Target position 0.091 mV / pulse
The signal level differs between signals. The output magnification can be switched individually.