CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
60
Command ID 26 Command
Name Parameter Value Check
Data Parameter ID
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation This command returns the parameter setting of Parameter ID.
Command ID 30 Command
Name Program Coordinate System
Data 0: Z phase
1: Program Origin
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation For a raster scan, the center of the oscillation angle can be changed.
0: Z phase
Set the Z-phase position as the center. This setting is in the default after activation.
1: Program Origin
Set the current position as the center.
When setting the program origin, move once to the desired center and then specify the
position by this command.
Command ID 40 Command
Name Monitor Output Selection (A2, A8)
Data 0: Encoder Head1 A phase
1: Encoder Head2 A phase
2: Corrected A phase
3: Position error
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation The output signal of analog monitor output A2 (the Axis1) and A8 (the Axis2) can be
selected.
When the controller starts, the 3: Position error has been selected.
(For details, see 5.2, “Analog Monitor Output Selecting ”)
Related
Command
Command ID = 44: Monitor Magnification Setting (A2, A8 )