CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
15
2.7. Control Specifications
The controller (GC-201, GC-101) is operated by:
RS-232C command input
High-speed serial communication
In addition, either the internal clock or external clock (high-speed serial communication) can be
selected for operation.
Internal Clock External Clock
(High-speed serial communication)
Clock input Clock pulses generated by the
controller internal circuit
High-speed serial communication
clock pulses
Target position
command
RS-232C command High-speed serial communication
command
(When RS-232C command input
mode is set, a high-speed serial
communication command is
ignored.)
Operation setting
parameter setting
RS-232C command RS-232C command
With the default settings at shipping, power-on activates the controller with the internal clock.
The parameter can be set so that the controller starts with the external clock after power-on.
For activation with the external clock, however, signal input by high-speed serial communication is
necessary at power-on.