7.2. Command Details
Command ID 0 Command
Name Soft Reset
Data 0: Reset + Automatic homing
1: Reset only
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation
This command resets the system to the initial status after activation.
However, the parameter values are retained.
If a high-priority error requiring soft reset occurs (see 9-2, “Errors” for details), execute
this command after solving the cause.
Related
Command
Command ID = 2: Homing Start
If only reset is executed, homing is necessary for a return.
Command ID 1 Command
Name Error Clear
Data -
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation
If a low-priority error occurs (see 9-2, “Errors” for details), execute this command for a
return. If this command is not executed, other commands cannot be accepted. The
parameters and other set values are retained.
Command ID 2 Command
Name Homing Start
Data -
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation
This command detects the origin.
If the status is already SYNC after origin detection, this command executes homing to
the origin only.
Related
Command
Command ID = 0: Soft Reset
If only soft reset is executed, origin detection is necessary.