Priority: Low
Error Hex Monitor Item Error Condition
Setting
Change
Possible
/Impossible
(Parameter)
System
status after
error
Digital
Output Recovery Method
Format error 0x0040 Command format An undefined command or parameter is
sent. Impossible
Error output
only
(Axis1)
Connector
B1
Monitor
Board
D2
(Axis2)
Connector
A3
Monitor
Board
D5
Error clearance
(C01)
Command data error
0x0080
Command data Command data is illegal.
No data is given to a command requiring
data.
Data is given to a command requiring no
data.
Data outside the setting range is set.
Impossible
Parameter error 0x0100 Parameter value A parameter value is beyond the setting
range. Impossible
Status error 0x0200 Command description A command not valid for the current status
is sent. Impossible
Communication error 0x0400 Communication flag Communication flag time-out occurs. Impossible
Out-position error
0x2000
Encoder pulse count The setting of P24 (Out-position Width) is
exceeded. Possible
(P24)