CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
71
Parameter ID 15 Parameter
Name
High-speed Serial Communication
Offset
Data High-speed Serial Communication Offset (Unit: pulse)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation Set this parameter, when a center position of the high-speed serial communications
data is offset.
This is effective, when operating by high-speed serial communications.
0 is set usually.
E.g. Data = 100
High-speed serial communication data(16bit) 0x8000 = 100 encoder pulse position.
Related
Command
/Parameter
Parameter ID 16 Parameter
Name
First Digital Notch Filter Central
Frequency
Data Central frequency of the first digital notch filter (Unit: Hz)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the central frequency of the first digital notch filter.
Related
Command
/Parameter
First Digital Notch Filter Q Value (Parameter ID = 17)
First Digital Notch Filter Depth (Parameter ID = 18)
Parameter ID 17 Parameter
Name First Digital Notch Filter Q Value
Data Q value of the first digital notch filter (Unit: ×100)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the Q value of the first digital notch filter.
Set a value multiplied by 100.
Related
Command
/Parameter
First Digital Notch Filter Central Frequency (Parameter ID = 16)
First Digital Notch Filter Depth (Parameter ID = 18)