CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
38
4.4. Position Command Input by High-speed Serial Communication
For a vector scan, give target position data to the controller by high-speed serial communication, The
data is updated as required.
Switch the controller to the status of receiving target position data by high-speed serial communication.
For switching, it is necessary to enter high-speed serial communication signals into the controller in
advance.
GALILEO
Select an axis for high-speed serial communication.
Switch HiSpeed Serial to Start.
This switching makes the controller follow target position data by high-speed serial communication.
Switch HiSpeed Serial to OFF.
Input of the MOVE command is awaited.
RS-232C commands
Switch to high-speed serial communication (Command ID = 23 Data = 7)
Return to internal clock operation (Command ID = 23 Data = 0)