Table 2 — Electrical Data Without VAV Option

 

 

 

 

EXHAUST AND SUPPLY MOTOR

HEATER

POWER SUPPLY

PRE-HEATER

DISCONNECT

UNIT SIZE

VOLTAGE

ERV WHEEL

 

(Optional)

 

 

SIZE

 

 

 

(Optional)

 

62M

(V-Ph-Hz)

FLA

NEC - FLA

Hp

(kW)

FLA

MCA

MOCP

FLA

Amps

Fuse Size*

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115-1-60

0.7

3.96

 

9.27

9.90

12.87

30

 

12

 

 

 

2

26.64

31.64

31.64

17.39

40

 

30

 

 

 

 

 

 

 

 

 

230-1-60

 

 

 

4.44

4.35

5.66

 

 

5

 

 

 

 

 

2

13.76

16.37

16.37

8.7

 

 

15

 

 

 

 

 

 

 

 

040

 

208/230-3-60

 

 

.6

4.11

4.35

5.66

 

 

5

 

0.3

1.74†

2

9.66

11.30

11.30

5.03

30

 

10

 

 

 

 

 

 

 

460-3-60

 

2.34

2.72

4.89

 

3

 

 

 

 

 

 

 

 

 

 

 

 

2

4.85

5.86

7.40

2.51

 

 

5

 

 

 

 

 

 

 

 

 

 

575-3-60

 

 

 

1.87

2.17

3.91

 

 

2

 

 

 

 

 

2

3.75

4.18

6.90

2.01

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20.69

24.5

31.85

40

 

30

 

 

115-1-60

0.7

9.8

 

2

38.08

46.24

49.24

17.39

60

 

45

 

 

 

 

 

 

5

64.17

78.85

78.85

43.48

100

 

70

 

 

 

 

 

 

10.46

12.25

15.93

30

 

15

 

 

230-1-60

 

4.9

 

2

19.16

23.12

24.62

8.7

 

20

 

 

 

 

 

 

 

 

 

 

 

 

5

32.2

39.42

39.42

21.74

60

 

35

 

 

 

 

 

 

5.03

5.50

7.15

 

 

6

075

 

208/230-3-60

 

2.2

0.5

2

10.05

11.78

12.18

5.03

 

 

12

 

 

 

0.3

 

 

5

17.59

21.21

21.21

12.57

 

 

20

 

 

 

 

 

2.53

2.75

3.58

 

 

4

 

 

 

 

 

 

 

 

 

 

460-3-60

 

1.1

 

2

5.04

5.89

6.09

2.51

30

 

6

 

 

 

 

 

 

5

8.81

10.60

10.60

6.28

 

 

10

 

 

 

 

 

 

2.10

2.25

2.93

 

 

3

 

 

575-3-60

 

0.9

 

2

4.11

4.76

4.94

2.01

 

 

5

 

 

 

 

 

 

5

7.13

8.53

8.53

5.03

 

 

8

 

 

 

 

 

 

33.09

40.00

52.00

60

 

50

 

 

115-1-60

0.7

16

 

2

50.48

61.74

69.39

17.39

80

 

60

 

 

 

 

 

 

5

76.57

94.35

95.48

43.48

200

 

90

 

 

 

 

 

 

16.66

20.00

26.00

30

 

25

 

 

230-1-60

 

8

 

2

25.36

30.87

34.70

8.70

40

 

30

 

 

 

 

 

 

5

38.40

47.17

47.74

21.74

60

 

45

 

 

 

 

 

 

9.03

10.50

13.65

30

 

12

120

 

208/230-3-60

 

4.2

1

5

14.05

16.78

18.68

5.03

30

 

18

 

 

 

0.3

 

 

8

21.59

26.21

26.22

12.57

40

 

25

 

 

 

 

 

4.53

5.25

6.83

 

 

6

 

 

 

 

 

 

 

 

 

 

460-3-60

 

2.1

 

2

7.04

8.39

9.34

2.51

 

 

8

 

 

 

 

 

 

5

10.81

13.10

13.11

6.28

30

 

12

 

 

 

 

 

 

3.70

4.25

5.53

 

5

 

 

 

 

 

 

 

 

 

 

575-3-60

 

1.7

 

2

5.71

6.76

7.54

2.01

 

 

6

 

 

 

 

 

 

5

8.73

10.53

10.55

5.03

 

 

10

 

 

 

 

 

 

16.93

20.00

26.00

30

 

25

 

 

230-1-60

 

8

 

5

38.67

47.17

47.74

21.74

60

 

45

 

 

 

 

8

51.71

63.48

63.48

34.78

80

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

10

60.41

74.35

74.35

43.48

100

 

70

 

 

 

 

 

 

9.33

10.50

13.65

30

 

12

 

 

208/230-3-60

 

4.2

 

5

21.90

26.21

26.22

12.57

40

 

25

 

 

 

 

8

29.44

35.63

35.63

20.11

60

 

35

 

 

 

 

 

 

 

170

 

 

0.6

 

1

10

34.46

41.91

41.91

25.13

60

 

40

 

 

 

4.69

5.25

6.83

30

 

6

 

 

 

 

 

 

 

 

 

460-3-60

 

2.1

 

5

10.97

13.10

13.11

6.28

30

 

12

 

 

 

 

8

14.74

17.82

17.82

10.05

30

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

10

17.26

20.96

20.96

12.57

30

 

20

 

 

 

 

 

 

3.88

4.25

5.53

30

 

5

 

 

575-3-60

 

1.7

 

5

8.90

10.53

10.55

5.03

30

 

10

 

 

 

 

8

11.92

14.30

14.30

8.04

30

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

10

13.93

16.82

16.82

10.05

30

 

15

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

ERV

Energy Recovery Ventilator

 

 

 

 

 

 

 

 

 

 

FLA

Full Load Amps

 

 

 

 

 

 

 

 

 

 

 

Hp

Horsepower

 

 

 

 

 

 

 

 

 

 

 

MCA

Minimum Circuit Amps

 

 

 

 

 

 

 

 

 

 

MOCP

Maximum Overcurrent Protection

 

 

 

 

 

 

 

 

 

 

NEC

National Electric Code

 

 

 

 

 

 

 

 

 

 

N/A

Not Applicable

 

 

 

 

 

 

 

 

 

 

 

*Fused disconnect only.

†Exhaust and supply fan motors are 230-1-60.