PLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING.

1

2

3

1

2

3

4

1

2

1

2

CN

BRN

ODC Th

 

 

 

 

 

 

BLK

ODA Th

 

 

 

 

 

 

 

 

CN

 

 

 

FAN MOTOR

 

 

 

 

 

 

 

BLK

 

1

BLK

 

 

 

 

 

 

 

 

 

 

 

BLU

 

2

BLU

 

 

 

 

 

 

 

 

 

 

 

RED

 

3

RED

 

 

 

GRN/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN/YEL

 

5

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

BRN

 

 

 

 

 

 

 

 

CONTROL EVAP.

 

 

 

 

 

 

BRN

BOX

 

 

 

 

 

 

WHT

WHT

 

 

 

 

 

 

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

OLP

 

 

 

 

 

 

 

(IF USED)

 

 

 

R

BLK(BLU)

RVC

 

1

2

 

YEL

C

 

 

 

 

 

 

 

 

 

(3)

 

S

 

 

 

 

 

 

 

LEGEND

CN :HOUSING CONNECTOR

PTC :START THERMISTOR OLP :OVERLOAD PROTECTOR RVC :REVERSING VALVE COIL

ODA Th :OUTDOOR AIR THERMISTOR ODC Th :OUTDOOR COIL THERMISTOR

F

CH CAPACITOR

RED BLU

RED

PTC

BLU

Figure 4--8 Heat Pump -- Upper Unit -- Ducted

LEGEND

IDC Th: INDOOR COIL THERMISTER

RA Th: ROOM AIR THERMISTER

ODC Th: OUTDOOR COIL THERMISTER

ODA Th :OUTDOOR AIR THERMISTOR

RVC: REVERSING VALVE COIL

D1: DIODE

K: RELAY

RA Th

BLK

CN1

 

 

1

 

 

 

CONTROL PCB

 

 

2

 

 

3

ASS’Y

 

 

4

 

 

 

IDC Th

BRN

 

 

CN9 1 2 3 4 5 6 7 8

CN9 1 2 3 4 5 6 7 8

DISPLAY PCB AS

 

 

 

 

PLUG CONNECTS TO UPPER UNIT.

 

 

 

NOTE

 

 

 

 

SEE DIAGRAM SUPPLIED WITH UPPER UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR ADDITIONAL WIRING.

 

 

*

FACTORY WIRING

 

 

 

 

 

 

 

 

ODC

ODA

 

 

 

 

 

 

COMPRESSOR

*

FIELD WIRING

RVC

 

MOTOR

 

(115VAC HIGH VOLT.)

1

2

3

1

2

1

2

3

4

2 1

 

*

FIELD WIRING

BLK

 

RED

WHT

BLK

 

BLU

GRN/YEL

 

WHT

 

(12VDC LOW VOLT.)

 

 

 

 

 

 

 

 

 

 

 

BLK

RED

 

 

 

 

 

BRN

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

CN5

 

 

1

2 CN5

1

2

3

4 CN3

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

 

 

 

 

 

 

 

 

 

BLK

2

2

2

 

 

 

 

 

 

 

L

 

3

3

3

 

K7

K2

K3

K4

K1

 

 

4

4

4

 

N2

 

115VAC POWER

 

 

 

 

 

 

 

 

5

5

5

 

 

 

 

 

 

 

N1

 

WHT

6

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN/YEL

7

7

7

 

 

 

 

 

 

 

 

8

8

8

POWER PCB ASS’Y

 

 

 

 

 

CN4

 

CN4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

 

 

 

 

 

FUSE

D1

 

RED

 

 

K6

 

 

 

 

 

2

(+)

2

2

2

 

 

 

 

 

 

 

 

 

 

 

250V 3.15A

1

 

(--)12VDC POWER

3

3

3

 

 

 

 

 

BLK

CN6

 

 

 

 

 

 

 

 

 

CN1

 

 

CN6

 

 

 

 

 

 

 

 

 

 

 

 

 

CN2

1 2

 

 

 

 

 

 

 

 

 

 

 

BLU

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FURNACE SIGNAL

 

 

Figure 4--9 Heat Pump -- Ceiling Unit -- Ducted

T--298

4-4

Page 46
Image 46
Carrier T--298 service manual Heat Pump -- Upper Unit -- Ducted