Carver CV Series user manual

Models: CV Series

1 27
Download 27 pages 47.31 Kb
Page 21
Image 21
Figure 16

and CV2 terminals. If you wish to control both channels simultaneously, using the remote control as a master level control and the front panel level controls as balance adjustments, both control inputs may be connected together and driven off the wiper of a single pot. (See figure 15) An example of this application would be in a system where the CV Series amplifier is being used to reproduce stereo information, and keeping two level controls synchronized during adjustment would be difficult.

"CH1 Level"

"CH2 Level"

 

 

 

 

R3

 

R1

R2

330

 

 

 

5kC

5kC

REDD1

"Amp On"

 

 

RTN

 

 

 

C2

 

 

 

C1

 

 

 

+5V

 

 

 

Figure 16

Connect the remaining terminal of the pot (full counter-clockwise position) to the +5V terminal of the “Remote Level” input connector.

This connection will set the control voltage to 0V with the pot rotated fully clockwise (sets maximum level), 5V with the pot rotated fully counter-clockwise (sets minimum level), and allow smooth variation between these extremes.

The VCA (voltage controlled amplifier) within the CV Series amplifier uses control information from the “Remote Level” input terminals in the flowing manner:

1)A 0V control voltage corresponds to 0dB added attenuation (added to the attenuation already set by the front panel Level control for that channel).

2)A 5V control voltage corresponds to 100dB added attenuation.

3)The control voltage effect is “dB linear”; a 2.5V control voltage input will add 50dB of attenuation.

4)The control characteristic is –1dB per 50mV of control voltage.

As an added bonus, low current loads, such as an LED, may be connected between the +5V and RTN terminals. This may be useful if one desires a visual indication that the CV Series amplifier is powered ON. The +5V at the “Remote Level” terminals turns on and off with the amplifier. (See figure 16)

Wiring Requirements for Remote Level Control Applications

For best results, use 24AWG or larger control wiring, especially for the +5V and RTN connections. Since 24AWG wire has DC resistance of 25mΩ per foot, using 1000 feet of 24AWG (loop resistance of 50Ω total) to make connection to a 5kΩ potentiometer will result in a 1% voltage drop, which causes a reduction in control

voltage range. This voltage drop increases as more current is carried by the +5V and RTN conductors,

i.e. when the 5V line is used to light a remote LED indicating that the amp is ON. In the (extreme) example given above, an additional 10mA load on the +5V and RTN conductors will cause 10% reduction in control voltage range, yielding lower maximum level and higher minimum level. Within reason, conductor capacitance is not a problem since the control voltages are averaged in the amplifier and any additional RC delay will not be noticeable.

Note: do not connect the RTN conductor to a ground reference at the remote control location. Ground potential differences will drive currents through the RTN line and cause unpredictable remote level control performance.

Rev 04.08.021

- 21 –

Page 21
Image 21
Carver CV Series user manual