WIRING
WARNING
To reduce the risk of SEVERE INJURY or DEATH: | • DO NOT install ANY wiring or attempt to run the operator |
• ANY maintenance to the operator or in the area near the | without consulting the wiring diagram. We recommend that |
operator MUST not be performed until disconnecting the | you install an optional reversing edge BEFORE proceeding |
electrical power and | with the control station installation. |
power switch. Upon completion of maintenance the area | • ALL power wiring should be on a dedicated circuit and well |
MUST be cleared and secured, at that time the unit may be | protected. The location of the power disconnect should be |
returned to service. | visible and clearly labeled. |
• Disconnect power at the fuse box BEFORE proceeding. | • ALL power and control wiring MUST be run in separate |
Operator MUST be properly grounded and connected in | conduit. |
accordance with local electrical codes. NOTE: The operator | • BEFORE installing power wiring or control stations be sure to |
should be on a separate fused line with a 15 amp | follow ALL specifications and warnings described below. |
circuit breaker. | Failure to do so may result in SEVERE INJURY to persons |
• ALL electrical connections MUST be made by a qualified | and/or damage to operator. |
individual. |
|
Connect Gate Operator (Gate 1) to Control Box
1Watertight Connector Nut
Insert operator cable through watertight connector nut.
Watertight Connector Nut
Operator
Cable
2 Insert Operator Cable
Insert watertight connector into the bottom of the control box and tighten with nut. Insert operator cable through watertight connector mounted in the bottom of the control box.
Nut
Watertight Connector
18
30 | 30 | Control Box |
Watertight
ConnectorOperator
Cable
Watertight
Connector Nut
| Can | Cause |
ng | Gateor Death | |
MoviInjury |
|
23 | Wiring |