PROGRAMMING

Program Limits

The limits are internal settings that indicate when the gates are in the fully open position and the fully closed position. For proper functionality, the limits must be learned during the installation process. The programmed limit process uses a combination of buttons on the control board.

The specific buttons used for programming depends on which side of the gates the control box is mounted on and how many operators the installation includes. Refer to pages 11-12 to determine if the gate is Left- or Right-handed and for explanation of PULL-TO-OPENand PUSH-TO-OPEN.

If a mistake is made during the programming process press the RESET button on the outside of the control box to start over.

Single Arm Left-Hand Side

Single Arm Right-Hand Side

NOTE: The “Learn Limits” mode can be exited at any time by pressing the RESET button. The mode will time-out automatically after 60 seconds of inactivity.

Program Open

With the gate in the closed position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).

LEARN LIMITS button

SET

OPEN

LIMIT

RESET

BUTTON

Press the GATE 1 right button to move gate to the desired OPEN position. When gate is in the desired position, press the LEARN LIMITS button again. Control board will beep.

DIAGNOSTIC

GATE 1

SET

CLOSE

Program Close

Press the GATE 1 left button to move gate to the desired CLOSED position. When gate is in the desired closed position, press the LEARN LIMITS button again.

DIAGNOSTIC

GATE 1

SET

CLOS

Program Open

With the gate in the closed position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).

LEARN LIMITS button

SET

OPEN

LIMIT

RESET

BUTTON

Press the GATE 1 left button to move gate to the desired OPEN position. When gate is in the desired position, press the LEARN LIMITS button again. Control board will beep.

DIAGNOSTIC

GATE 1

SET

CLOS

Program Close

When the SET CLOSE LIMIT LED blinks, press the GATE 1 right button. When gate is in the desired closed position, press the LEARN LIMITS button.

DIAGNOSTIC

GATE 1

SET

CLOSE

The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete.

Test the limits by pressing the SBC to open and close the gate.

NOTE: If the SET OPEN LIMIT LED is still blinking, the limits were not programmed successfully. Repeat the programming making sure the gate is fully opened and closed for each respective limit. If the problem persists, refer to the

Troubleshooting section.

 

Programming

32