Operator Specifications
Main Supply (Motor)

12Vdc Battery run. Operational between 11.5Vdc and 14.5Vdc.

Accessory Power

12V nominal Class II battery voltage source is limited to:

 

• Solar or AC Cable up to 50' - 500 mA

 

• AC Cable 50' up to 250' - 250mA

 

• AC Cable 250' up to 1000' - 100mA

 

NOTE: Increased accessory power drawn from the operator will shorten the

 

battery life.

Power Consumption

30 Watts max (during battery charging)

Battery Charger Supply

14.5Vac nominal, 30 VA max.

Maximum Gate Length

18 ft. at 350 lbs.

Maximum Gate Weight

850 lbs. at 6 ft.

Travel Time

20 seconds (typical)

Temperature

-20ºC to +50ºC, -4ºF to 122ºF Contact Technical Support for applications

 

below -20ºC

Protection Fuse Battery 1

ATC 20A

Protection Fuse Battery 2

ATC 20A

3