To Open the Door Manually

THE REMOTE CONTROL BATTERY

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:

If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly.

NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.

NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.

DISCONNECT THE TROLLEY:

 

Trolley

 

The door should be fully closed

 

 

if possible. Pull down on the

 

 

 

emergency release handle (so

 

 

 

that the trolley release arm

 

Trolley

 

snaps into a vertical position)

 

 

 

Release Arm

 

and lift the door manually.

 

 

 

(In Manual

 

The lockout feature prevents

 

 

 

Disconnect

 

the trolley from reconnecting

 

Position)

 

automatically, and the door can

 

 

be raised and lowered manually

Lockout position

 

as often as necessary.

 

 

 

(Manual disconnect)

 

 

TO RE-CONNECT THE

 

 

 

TROLLEY:

 

Trolley

 

Pull the emergency release

 

 

 

handle toward the opener at

 

 

 

an angle so that the trolley

 

 

Trolley

release arm is horizontal.

 

 

 

 

Release

The trolley will reconnect

 

 

Emergency

Arm

on the next UP or DOWN

 

operation, either manually

Release Handle

 

(Down and Back)

 

or by using the door control

 

or remote.

To reconnect

 

To prevent possible SERIOUS INJURY or DEATH:

NEVER allow small children near batteries.

If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn:

Replace ONLY with 3V2032 coin batteries.

DO NOT recharge, disassemble, heat above 100° C (212° F) or incinerate.

The lithium battery should produce power for up to 5 years.

To replace battery, use the visor

Battery

clip or screwdriver blade to pry

positive

open the case as shown. Insert

side up (+)

battery positive side up (+).

 

Dispose of old battery properly.

Replace the battery with ONLY 3V2032 coin cell batteries.

NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

Tested to Comply with FCC Standards for Home or office use. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Care of Your Opener

MAINTENANCE SCHEDULEEvery Month

Manually operate door. If it is unbalanced or binding, call a trained door systems technician.

Check to be sure door opens & closes fully. Adjust limits and/or force if necessary (See pages 28 and 29).

Repeat the safety reverse test. Make any necessary adjustments (See Adjustment Step 3).

Every Year

Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.

34