Instruction Manual | |
|
|
INSIDE TERMINAL WIRING EXAMPLES
The information on the following pages cover the most common wiring options:
•Supplied Momentary Push Button
•Discrete Extend and Retract for Switch or Dry Contacts
•12 Volt out supply
•24 Volt out supply
•Two dry contact closures
•Voltage Sensing
•Service Extend
CAUTION: Closing the unit while the projector is running may cause premature bulb failure and may damage both the lift and pro- jector.
Push Button
Supplied Single Pole Single Throw (SPST) Switch Using Internal 24VAC Power Supply
a.Connect the green jumper wire (supplied) to terminals 2 & 6 (see Figure 17).
b.Connect the SPST switch (supplied) to terminals 1 & 5.
Supplied SPST Switch Using Internal 12VDC Power Supply
a.Connect the green jumper wire (supplied) to terminals 6 & 10 (see Figure 18).
b.Connect the SPST switch (supplied) to terminals 4 & 5.
Supplied SPST Switch Using External Power Supply.
a.Connect the negative of your power supply to terminal 6 (see Figure 19).
b.Connect the SPST switch (supplied) to terminal 5 & the pos- itive of your power supply.
Figure 17. 24VAC Internal
Figure 18. 12DC Internal
Figure 19. External Power Supply
16