INSIDE TERMINAL WIRING EXAMPLES

Instruction Manual

SMART-LIFT 236 Electric Ceiling Lifts

 

 

INSIDE TERMINAL WIRING EXAMPLES

The information on the following pages cover the most common wiring options:

Supplied Momentary Push Button

Discrete Extend and Retract for Switch or Dry Contacts

12 Volt out supply

24 Volt out supply

Two dry contact closures

Voltage Sensing

Service Extend

CAUTION: Closing the unit while the projector is running may cause premature bulb failure and may damage both the lift and pro- jector.

Push Button

Supplied Single Pole Single Throw (SPST) Switch Using Internal 24VAC Power Supply

a.Connect the green jumper wire (supplied) to terminals 2 & 6 (see Figure 17).

b.Connect the SPST switch (supplied) to terminals 1 & 5.

Supplied SPST Switch Using Internal 12VDC Power Supply

a.Connect the green jumper wire (supplied) to terminals 6 & 10 (see Figure 18).

b.Connect the SPST switch (supplied) to terminals 4 & 5.

Supplied SPST Switch Using External Power Supply.

a.Connect the negative of your power supply to terminal 6 (see Figure 19).

b.Connect the SPST switch (supplied) to terminal 5 & the pos- itive of your power supply.

Figure 17. 24VAC Internal

Figure 18. 12DC Internal

Figure 19. External Power Supply