Chief Manufacturing SL-236 0.5 AMP@125VAC, 0.3 AMP@60VDC, range may adjust travel limits

Models: SL-236

1 24
Download 24 pages 5.39 Kb
Page 20
Image 20
range may adjust travel limits.

Instruction Manual

SMART-LIFT 236 Electric Ceiling Lifts

 

 

 

 

Extends unit to preset travel limit.

 

 

If using Latching Switch, be sure to

11

 

 

 

 

EXTEND

Customer within a preset maximum

 

 

disengage Switch prior to initiating any

 

 

 

other function.

 

 

range may adjust travel limits.

 

 

 

 

 

 

 

 

 

 

 

 

Momentary or Latching contact to

 

 

 

 

 

 

 

 

 

Retracts unit to preset travel limit.

 

Ground terminals 3, 10, 13, or 20.

 

 

 

 

 

 

 

 

12

 

 

 

 

If using Latching Switch, be sure to

RETRACT

Travel limits may be adjusted by

 

 

disengage Switch prior to initiating any

 

 

customer within a preset maximum

 

 

other function.

 

 

range.

 

 

 

 

 

 

 

 

 

 

 

13

GROUND

Ground

 

 

 

 

 

 

 

 

 

 

 

14

EXTEND

Immediately reverses direction of

 

 

Chief Mfg. offers the SS-10 Pressure

travel when triggered while unit is

 

 

Sensitive Safety Strip to provide this

ERROR

 

 

extending.

 

 

function.

 

 

 

Momentary contact to Ground

 

 

 

 

Please specify how many inches required

 

 

 

 

terminals 3, 10, 13, or 20.

 

 

Immediately reverses direction of

 

spanning entire pinch zone.

 

 

 

 

15

RETRACT

 

 

The SS-10 must be ordered with the ST-15

travel when triggered while unit is

 

 

ERROR

 

 

Terminals.

retracting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

EXTEND

 

 

 

 

 

LIMIT

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

Closes set of internal dry contacts

 

 

RATED FOR 11AMP.0 AMP@30VDC24 VOLTS

 

 

 

 

 

 

when unit reaches full extension.

 

 

 

EXTEND

 

 

0.5 AMP@125VAC

 

 

 

 

17

LIMIT

 

 

 

0.3 AMP@60VDC

RELAY

 

 

 

 

 

 

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

18

RETRACT

 

 

 

 

 

LIMIT

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

Closes set of internal dry contacts

 

 

RATED FOR 11AMP.0 AMP@30VDC24 VOLTS

 

 

 

 

 

RETRACT

when unit reaches full retraction.

 

 

0.5 AMP@125VAC

 

 

 

 

0.3 AMP@60VDC

19

LIMIT

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

COMMON

 

 

 

 

 

20

GROUND

Ground

19

Page 20
Image 20
Chief Manufacturing SL-236 0.5 AMP@125VAC, 0.3 AMP@60VDC, range may adjust travel limits, Momentary contact to Ground