Instruction Manual | |
|
|
|
|
SMART LIFT EXTERIOR 14 PIN
TERMINAL FUNCTION DEFINITION
TERMINAL | FUNCTION | |
NUMBER | ||
| ||
|
| |
1 | 24 VOLT AC | |
|
|
DESCRIPTION
24 volt AC output
WIRING OPTIONS | NOTES |
This is an internal power supply for powering external devices & Remote Controllers.
2 |
|
|
| Chief Mfg. offers the | ||
24 VOLT AC | 24 volt AC common |
| Frequency Remote Controller which runs | |||
| COMMON |
|
| off of this power supply. |
| |
|
| Retracts unit to preset travel limit. |
| If using Latching Switch, be sure to | ||
3 |
|
|
| |||
RETRACT | Travel limits may be adjusted by |
| disengage Switch prior to initiating any | |||
|
| other function. | ||||
|
| customer within a preset maximum |
| |||
|
| Momentary or Latching contact to |
|
| ||
|
| range. |
|
| ||
|
| Ground terminals 9, or 11. |
|
| ||
4 |
| Extends unit to preset travel limit. | If using Latching Switch, be sure to | |||
|
| |||||
EXTEND | Customer within a preset maximum |
| disengage Switch prior to initiating any | |||
|
|
| other function. | |||
|
| range may adjust travel limits. |
|
|
| |
| EXTEND/ | Used in conjunction with | To Operate using Internal Power | NOT TO BE USED AS GROUND FOR | ||
5 | Extend/Retract when using an | Source | ||||
RETRACT | FUNCTION OTHER THAN | |||||
external power source to initiate | Connect terminals 9 & 5 with | |||||
COMMON | EXTEND/RETRACT TERMINAL 5. | |||||
| movement. | Jumper Wire. Connect | ||||
|
|
|
| |||
|
|
| Momentary Switch to terminal |
|
| |
|
|
| 10. Connect other line of |
|
| |
|
|
| Momentary Switch to terminal 6. |
|
| |
|
| Initiates movement if lift is static, or |
| Function operates on momentary switch | ||
6 | EXTEND/ | stops movement if lift is in motion. | To Operate using External Power | only. | ||
RETRACT | Direction of travel will be opposite | Source |
|
| ||
|
| of last direction of travel. | Connect External Power Supply’s | Operating range is 5 – 30 Volts AC or DC. | ||
|
|
| Common to terminal 5. Connect |
|
| |
|
|
| initiating signal to terminal 6. |
|
| |
7 | RETRACT | Immediately reverses direction of |
|
|
| |
travel when triggered while unit is |
| Chief Mfg. offers the | ||||
ERROR |
| |||||
retracting. |
| Sensitive Safety Strip to provide this | ||||
|
|
| ||||
|
|
| Momentary contact to Ground | function. | ||
|
|
| Please specify how many inches required | |||
|
| Immediately reverses direction of | terminals 9, or 11. | |||
8 | EXTEND | to span entire pinch zone. | ||||
travel when triggered while unit is |
| |||||
ERROR |
| The | ||||
extending. |
| |||||
|
|
| Terminals. | |||
|
|
|
| |||
|
|
|
|
|
| |
9 | GROUND | Ground |
| This is an internal power supply for | ||
|
|
|
| powering external devices &/or used for | ||
10 |
|
|
| initiating specific functions | ||
12 VOLT DC | 12 volt DC |
| (Extend/Retract 6). | |||
|
|
|
|
|
| |
|
| Extends unit to maximum limit, |
| Feature not available on all models. | ||
11 |
| bypassing | Momentary or Latching contacts |
|
| |
Service Extend | Often used for servicing projectors | to Ground terminals 3, 10, 13, or | If using Latching Switch, be sure to | |||
|
| 20 | disengage Switch prior to initiating any | |||
|
| in ceiling lifts. |
| other function |
|
20