OUTSIDE TERMINAL WIRING EXAMPLES

Instruction Manual

SMART-LIFT 236 Electric Ceiling Lifts

 

 

 

 

OUTSIDE TERMINAL WIRING EXAMPLES

The information on the following pages cover the most common wiring options:

Supplied Momentary Push Button

Discrete Extend and Retract for switch or dry contacts

12 Volt out supply

24 Volt out supply

Two dry contact closures

Service Extend

CAUTION: Closing the unit while the projector is running may cause premature bulb failure and may damage both the lift and pro- jector.

Push Button

Figure 13. 24VAC Internal

Supplied Single Pole Single Throw (SPST) Switch

Using Internal 24VAC Power Supply

a.Connect the green jumper wire (supplied) to terminals 1 & 5 (see Figure 13).

b.Connect the SPST switch (supplied) to terminals 2 & 6.

Supplied SPST Switch Using Internal 12VDC Power Supply

a.Connect the green jumper wire (supplied) to terminals 5 & 9 (see Figure 14).

b.Connect the SPST switch (supplied) to terminals 6 & 10.

Supplied SPST Switch Using External Power Supply

a.Connect the negative of your power supply to terminal 5 (see Figure 15).

Figure 14. 12DC Internal

b.Connect the SPST switch (supplied) to terminal 6 & the pos- itive of your power supply.

Figure 15. External Power Supply