Multigigabit Crossbar Switch Fabric

System clock—The system clock synchronizes data transfers between line cards or between the RP and a line card, through the switch fabric. In systems with redundant CSCs, the two system clocks are synchronized so that if one system clock fails, the other clock takes over. The system clock signal is sent to all line cards, the RP, and switch fabric cards.

Scheduler—The scheduler handles requests from the line cards for access to the switch fabric. When the scheduler receives a request from a line card for switch fabric access, the scheduler determines when to allow the line card access to the switch fabric.

Switch fabric—The switch fabric carries the user traffic between line cards or between the RP and the line cards. The switch fabric card contains only the switch fabric circuitry and receives scheduling information and system clock information from the CSC.

The SFC contains only the switch fabric circuitry, which carries user traffic between line cards or between the RP and the line cards. The SFC receives scheduling information and the system clock sent from the CSC.

Nonredundant and Redundant System Configurations

Cisco 12006 and Cisco 12406 routers are available in two system configurations:

1.Nonredundant configuration that includes one CSC and one power supply.

When you order a Cisco 12006 or Cisco 12406 Router, the nonredundant configuration is shipped by default.

2.Redundant configuration that includes two CSCs and two power supplies.

For the redundant configuration, EMI compliance and cooling requirements are met by having two CSCs and two power supplies installed in the system.

For the nonredundant configuration, EMI compliance and cooling requirements are met only when blank fillers are installed in place of either (or both) the second (unused) CSC slot or the second (unused) power supply bay.

Note When operating your router with a single CSC, the second CSC slot must have a CSC blank filler (MAS-GSR6-CSCBLNK=) installed to ensure EMI compliance.

 

 