Interface Numbering

Chapter 2 Overview of Cisco 1800 Series Routers (Modular)

Interface Numbering

1

Input power connection

8

CompactFlash memory card slot

 

 

 

 

2

On/Off switch

9

CompactFlash (CF) LED

 

 

 

 

3

Slot 0 (WIC, VWIC—data only, or HWIC)

10

AIM LED

 

 

 

 

4

Console port

11

USB port

 

 

 

 

5

Fast Ethernet ports and LEDs

12

Aux port

 

 

 

 

6

KensingtonTM security slot

13

Chassis ground connection

7

Slot 1 (WIC, VWIC—data only, or HWIC)

 

 

 

 

 

 

Interface Numbering

Each individual interface (port) on a Cisco 1841 router is identified by a number. A Cisco 1841 router contains the following wide-area network (WAN) and local-area network (LAN) interface types:

Two onboard Fast Ethernet LAN interfaces

Two slots in which you can install WICs, VWICs (data only), and HWICs.

The numbering format for the slots is interface-type 0/slot-number/interface-number.Table 2-6summarizes the interface numbering.

Table 2-6

Interface Numbering

 

 

 

 

 

 

 

Slot Number

 

Slot Type

Slot Numbering Range

Example1

Onboard Ports

 

Fast Ethernet

0/0 and 0/1

interface fastethernet 0/0

 

 

 

 

 

Slot 0

 

HWIC/WIC/VWIC2

0/0/0 to 0/0/3

interface serial 0/0/0

 

 

 

 

line async 0/0/0

 

 

 

 

 

Slot 1

 

HWIC/WIC/VWIC2

0/1/0 to 0/1/3

interface serial 0/1/0

 

 

 

 

line async 0/1/0

 

 

 

 

 

1.The interfaces listed are examples only; other possible interface types are not listed.

2.VWICs are data-only in a Cisco 1841 router.

Note On the Cisco 1841 router, the numbering format for configuring an async interface is 0/slot/port. To configure the line associated with an async interface, simply use the interface number to specify the async line. For example, line 0/0/0 specifies the line associated with interface serial 0/0/0 on a WIC-2A/S in slot 0. Similarly, line 0/1/1 specifies the line associated with interface async 0/1/1 on a WIC-2AM in slot 1.