Cisco Systems N5KC5596TFA manual Viewing An Interface-Specific Type-1 Inconsistency

Models: N5KC5596TFA

1 122
Download 122 pages 34.07 Kb
Page 110
Image 110
Viewing An Interface-Specific Type-1 Inconsistency

Configuring Virtual Port Channels

Viewing An Interface-Specific Type-1 Inconsistency

20

Po20

up

failed

Global

compat

check

failed

1-10

30

Po30

up

failed

Global

compat

check

failed

1-10

Viewing An Interface-Specific Type-1 Inconsistency

When an interface-specific Type-1 inconsistency occurs, the vPC port on the secondary switch is brought down while the primary switch vPC ports remain up.The following example shows this type of inconsistency when there is a switchport mode mismatch.

This example shows how to display the status of the suspended vPC VLAN on the secondary switch:

switch(config-if)# show vpc brief Legend:

(*) - local vPC is down, forwarding via vPC peer-link

vPC domain id

:

10

Peer status

:

peer adjacency formed ok

vPC keep-alive status

:

peer is alive

Configuration consistency status:

success

Per-vlan consistency status

:

success

Type-2 consistency status

:

success

vPC role

:

secondary

Number of vPCs configured

:

2

Peer Gateway

:

Disabled

Dual-active excluded VLANs

:

-

Graceful Consistency Check

:

Enabled

vPC Peer-link status

---------------------------------------------------------------------

id Port Status Active vlans

------ ------ --------------------------------------------------

1 Po1 up 1

vPC status

----------------------------------------------------------------------------

id

Port

Status

Consistency

Reason

Active vlans

------

-----------

------

-----------

--------------------------

-----------

20

Po20

up

success

success

1

30

Po30

down*

failed

Compatibility check failed

-

 

 

 

 

for port mode

 

This example shows how to display the inconsistent status ( the VLANs on the primary vPC are not suspended) on the primary switch:

switch(config-if)# show vpc brief Legend:

(*) - local vPC is down, forwarding via vPC peer-link

vPC domain id

:

10

Peer status

:

peer adjacency formed ok

vPC keep-alive status

:

peer is alive

Configuration consistency status:

success

Per-vlan consistency status

:

success

Type-2 consistency status

:

success

vPC role

:

primary

Number of vPCs configured

:

2

Peer Gateway

:

Disabled

Dual-active excluded VLANs

:

-

Graceful Consistency Check

:

Enabled

vPC Peer-link status

---------------------------------------------------------------------

id Port Status Active vlans

------ ------ --------------------------------------------------

1 Po1 up 1

vPC status

 

Cisco Nexus 5000 Series NX-OS Interfaces Configuration Guide, Release 5.2(1)N1(1)

98

78-26881-OL

Page 110
Image 110
Cisco Systems N5KC5596TFA manual Viewing An Interface-Specific Type-1 Inconsistency, Compatibility check failed