Cisco Systems N5KC5596TFA manual vPC Default Settings, Parameters

Models: N5KC5596TFA

1 122
Download 122 pages 34.07 Kb
Page 117
Image 117
vPC Default Settings

Configuring Virtual Port Channels

vPC Default Settings

Step 7 Configure a vPC server port on on the Fabric Extender NX-2000-100.

NX-5000-1(config-if)#interface ethernet 100/1/1

NX-5000-1(config-if)# switchport mode trunk

NX-5000-1(config-if)#switchport trunk native vlan 100

NX-5000-1(config-if)#switchport trunk allowed vlan 100-105

NX-5000-1(config-if)# channel-group 600

NX-5000-1(config-if)# no shutdown

NX-5000-1(config-if)# exit

NX-5000-1(config)#interface port-channel 600

NX-5000-1(config-if)# vpc 600

NX-5000-1(config-if)# no shutdown

NX-5000-1(config-if)# exit

Step 8 Save the configuration.

NX-5000-1(config)#copy running-config startup-config

vPC Default Settings

The following table lists the default settings for vPC parameters.

Table 8: Default vPC Parameters

 

Parameters

Default

vPC system priority

32667

vPC peer-keepalive message

Disabled

vPC peer-keepalive interval

1 second

vPC peer-keepalive timeout

5 seconds

vPC peer-keepalive UDP port

3200

Cisco Nexus 5000 Series NX-OS Interfaces Configuration Guide, Release 5.2(1)N1(1)

78-26881-OL

105

Page 117
Image 117