Changing Switch Number 3 to Switch Number 2 New Switch Number will be effective after next reboot

6. Exit the configuration mode, as follows:

At this prompt...

Enter...

 

Notes

 

 

 

 

 

 

sw01#

exit

 

 

 

7. Halt and perform a cold restart, as follows:

 

 

 

 

 

 

 

At this prompt...

Enter...

Notes

 

 

 

 

 

 

sw01>

reload

 

 

 

System configuration has been modified.

no

 

 

 

Save? [yes/no]:

 

 

 

 

Proceed with reload? [confirm]

y

Displays the following output:

 

00:08:23: %SYS-5-RELOAD: Reload requested

Base ethernet MAC Address: 00:11:bb:7e:94:80 Xmodem file system is available.

The password-recovery mechanism is enabled. Initializing Flash...

flashfs[0]: 79 files, 4 directories

flashfs[0]: 0 orphaned files, 0 orphaned directories

flashfs[0]: Total bytes: 15998976

flashfs[0]: Bytes used: 6457856

flashfs[0]: Bytes available: 9541120

flashfs[0]: flashfs fsck took 8 seconds.

...done Initializing Flash.

Boot Sector Filesystem (bs) installed, fsid: 3 done.

...

Press RETURN to get started!

Proceed to step 1 in Setting switch options on page 24 to continue the switch configuration procedure.

Setting switch options

This procedure provides the minimal configuration required to support the reference system. Configure the first switch stack as follows:

1. Select the Enter key to get started. Skip the initial configuration, as follows:

At this prompt...

Enter...

Notes

 

 

 

--- System Configuration Dialog ---

no

 

would you like to enter the initial configuration

 

 

dialog? [yes/no]:

 

 

CASSATT ACTIVE RESPONSE CONTROL NODE AND NETWORK SWITCH CABLING EXAMPLE

24

Page 9
Image 9