Citizen iDP3310 manual Citizen

Models: iDP3310

1 87
Download 87 pages 27.23 Kb
Page 41
Image 41

iDP3310 User's Manual

7.3.2Data Configuration

Mark

Space

t

 

b0, b1, b2,

 

(1)

 

(2)

(3)

(1)

Start Bit

 

(2)

Data Bit (+ Parity Bit)

 

(3)

Stop Bit (1 or More)

 

(1)Start bit

In 1/2 bit from the Mark-to-Space starting edge, state is read once again. When "Space" state is confirmed, it is recognized as the start bit. If it is "Mark" state, it is not taken as the start bit. Without taking it as an error, detection of a start bit is carried out once again.

(2)Data Bit + Parity Bit

Data bit and parity bit are sampled at 1/2 start bit for time length equal to 1 bit. The state thus sampled is taken as the data for the bit concerned. Bits are named as Bit 0, Bit 1, ..., parity bit counted from the one close to the start bit.

(3)Stop bit

The stop bit is a mark level of 1 bit or more. With "Space" having been detected on detection of a stop bit, framing error takes place.