CBM-920 User’s Manual

2)Input Signal Level (RESET) The input signal level is at TTL.

"HIGH" level : 2.4V MIN

"LOW" level : 0.4V MAX

3)Output Signal Level (FAULT, PE) The output signal level is at TTL. For TTL level

"HIGH" level : 2.4V MIN

"LOW" level : 0.4V MAX

6.5Error Detection

Communication Error

1)

Parity Error

In checking of odd/even parity based on parity checking assignment, when parity is

 

 

found nonconforming.

 

 

2)

Framing Error

In detection of stop bit when space state has been detected.

 

 

3)

Overrun Error

Regardless of data being held in receiving buffer register, when next data are

 

 

transmitted to the receiving buffer register.

 

 

On occurrence of the above mentioned error, the data concerned is converted into '

' (7FH) which is

printed.

29