Citizen Systems CBM-920 manual DIP Switch Setting, DS1

Models: CBM-920

1 59
Download 59 pages 7.83 Kb
Page 37
Image 37

CBM-920 User’s Manual

7.DIP SWITCH SETTING

DS1

Switch No.

Function

OFF

ON

Factory Setting

 

 

 

 

 

1

 

 

 

*

2

International character

See the table below

 

*

3

 

 

 

 

 

 

 

*

 

 

 

 

 

4

CR function

CR ignored

CR + LF

OFF

 

 

 

 

 

5

Character direction

Erecting character

Inverted character

OFF

 

 

 

 

 

6

Paper near end function

Enabled

Disabled

OFF

 

 

 

 

 

7

Auto loading function

Enabled

Disabled

OFF

 

 

 

 

 

8

Hex. Dump mode

Disabled

Enabled

OFF

 

 

 

 

 

 

 

 

 

 

* changes in setting according to destination.

 

 

 

 

 

 

 

 

Hex. Dump mode is not available with 24 columns version.

 

International Character Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

International

 

 

 

 

 

 

 

 

 

 

 

Character

U.S

France

Germany

U.K

Denmark

Italy

 

Spain

 

Japan

 

Setting

 

 

 

Switch No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

OFF

ON

OFF

ON

OFF

ON

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

2

OFF

OFF

ON

ON

OFF

OFF

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

3

OFF

OFF

OFF

OFF

ON

ON

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

DS2

 

Switch No.

Function

OFF

ON

Factory Setting

 

 

 

 

 

 

 

 

 

 

1

Bit length

8 bits

7 bits

OFF

 

 

 

 

 

 

 

 

 

 

2

Parity

No

Yes

ON

 

 

 

 

 

 

 

 

 

 

3

Parity conditions

Odd

Even

OFF

 

 

 

 

 

 

 

 

 

 

4

Baud rate

See the table below.

OFF

 

 

 

 

5

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate (bps) Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch No.

1,200

 

2,400

 

4,800

 

9,600

 

 

 

 

 

 

 

 

 

 

4

OFF

 

ON

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

5

OFF

 

OFF

 

ON

 

ON

 

 

 

 

 

 

 

 

 

* DS2 setting is available only for Serial interface

31

CITIZEN

Page 37
Image 37