CBM-920 User’s Manual

<Print result>

(3)Data cancellation (CAN) command

In inputting of CAN (18H) code, all of the data before CAN code at same one line is canceled.

<Receiving data>

S O

1 2 3 4 5 6

CAN

A B C

C R

<Print result>

(4)Inverted character specifying (DC2) command

By inputting data adding DC2 (12H) into the beginning of the line, (in case of adding this command into the position except for the beginning of line, this command is ignored.) all of the data after this command is printed at inverted character.

Cancellation of inverted character is conducted by inputting DC2 again or DC1 (initial setting).

In case inverted character is specified by dip switch setting, all of this operation goes to opposite way.

35